Thiết bị mạng Ruckus ICX 7650-48P Gigabit Ports with PoE Switch.
Performance and Scalability ICX 7650-48P | |
Switching capacity (data rate, full duplex, stacking enabled) | 696 Gbps |
Forwarding capacity (data rate, full duplex, stacking enabled) | 518 Mpps |
Fixed ports: 10/100/1000 Mbps RJ45 downlinks | 48 |
Modular ports 1/10 Gbps SFP/ SFP+ uplinks (max.) | 4 |
40 Gbps QSFP+ ports (max.) | 2 Fixed or 2 Modular |
100 Gbps QSFP28 ports (max.) | 2 Fixed (Stacking Only) |
Stacking ports (max ports usable for stacking) | 4×40G QSFP+ or 2×100G QSFP28 |
PoE / PoE+ ports | 40 |
802.3bt ports (90 W per port) Compatible with PoE/PoE+/Cisco uPoE | 8 |
Maximum PoE Class 3 ports (15.4 W per port) | 48 |
Maximum PoE+ Class 4 ports (30 W per port) | 48 (2 PSU) |
Base IPv4/v6 Layer 3 routing (static routing, RIP) | Standard |
Advanced IPv4/v6 Layer 3 routing (OSPF, BGP, VRRP, PIM, PBR, VRF) | With license |
Aggregated stacking bandwidth | 2.4 Tbps |
Stacking density (maximum switches in a stack) | 12 |
Maximum stacking distance (distance between stacked switches) | 10 km |
Campus Fabric | Fabric Control Bridge (CB) |
Power ICX 7650-48P | |
Power inlet (AC) | C14 |
Input voltage/frequency | AC: 100 to 240 VAC @ 50 to 60 Hz |
Power supply rated maximum | 2 x 1000W |
PoE power budget (two power supplies) | 1500 W |
Switch power consumption3 (25°C) Idle (no PoE load) 10% traffic4 (full PoE load) 100% traffic4 (full PoE load) |
66 W895 W
901 W |
Airflow | front-to-back, or back-to-front (depending on power supplies and fans installed) |
Switch heat dissipation (25°C)3 Idle (no PoE load) 10% traffic2 (full PoE load) 100% traffic2 (full PoE load) |
226BTU/hour
391 BTU/hour 408 BTU/hour |
ENVIRONMENT ICX 7650-48P | |
Net Weight (Kg) | 7.5 kg (16.53 lb) |
Dimensions (mm) | 440mm (17.323 in.) W x 406mm (15.984 in.) D x 44mm (1.732 in.) H; 1U |
Acoustics (25°C, min fan speed) | 48.3 dBA |
MTBF (25°C) | 213,026 hours |
SPECIFICATIONS ICX 7650-48P | |
DRAM | 4 GB |
NVRAM (Flash) | 16 GB |
Packet buffer size | 5 MB |
Maximum MAC addresses | 80,000 |
Maximum VLANs Maximum PVLANs |
• 4,095 • 256 |
Maximum VEs | 512 |
Maximum routes (in hardware) | • 128K (IPv4) • 7K (IPv6) • 12,000 (Next Hop Addresses) |
Trunking | • Maximum ports per trunk: 16 • Maximum trunk groups: 256 |
Maximum jumbo frame size | 9,216 bytes |
QoS priority queues | 10 for Unicast and Multicast traffic |
Multicast groups | • 8,192 (Layer 2) • 8,192 (Layer 3) |
VRF | 50 instances |
FEATURE SETS ICX 7650-48P | |
Layer 2 feature set | • 802.1s Multiple Spanning Tree • 802.1x Authentication • Auto MDI/MDIX • BPDU Guard, Root Guard • Dual-Mode VLANs • MAC-based VLANs, Dynamic MAC-based VLAN activation • Dynamic Voice VLAN Assignment • Dynamic VLAN Assignment • Fast Port Span • GVRP: GARP VLAN Registration Protocol • IGMP Snooping (v1/v2/v3) • IGMP Proxy for Static Groups • IGMP v2/v3 Fast Leave • Inter-Packet Gap (IPG) adjustment • Link Fault Signaling (LFS) • MAC Address Filtering • MAC Learning Disable • MLD Snooping (v1/v2) • Multi-device Authentication • Per-VLAN Spanning Tree (PVST/PVST+/PVRST) • Mirroring – Port-based, ACL-based, MAC Filter-based, and VLAN-based • PIM-SM v2 Snooping • Port Loop Detection • Private VLAN • Remote Fault Notification (RFN) • Single-instance Spanning Tree • Trunk Groups (static, LACP) • Uni-Directional Link Detection (UDLD) • Metro-Ring Protocol (MRP) (v1, v2) • Virtual Switch Redundancy Protocol (VSRP) • Q-in-Q and selective Q-in-Q • VLAN Mapping • Topology Groups |
Base Layer 3 IP routing | • IPv4 and IPv6 static routes − RIP v1/v2, RIPng • ECMP • Port-based Access Control Lists • Layer 3/Layer 4 ACLs • Host routes • Virtual interfaces • Routed interfaces • Route-only support • Routing between directly connected subnets |
Premium Layer 3 IP routing (require license) | • IPv4 and IPv6 dynamic routes • OSPF v2, OSPF v3 (IPv6) • PIM-SM, PIM-SSM, PIM-DM, PIM passive (IPv4/IPv6 multicast routing functionality) • PBR • Virtual Route Redundancy Protocol VRRP v3 (IPv6) • VRRP-E (IPv4, IPv6) • BGP4, BGP4+ (IPv6) • GRE • IPv6 over IPv4 tunnels • VRF (IPv4 and IPv6) • MSDP |
Quality of Service (QoS) | • ACL Mapping and Marking of ToS/DSCP • ACL Mapping and Marking of 802.1p • ACL Mapping to Priority Queue • Classifying and Limiting Flows Based on TCP Flags • DiffServ Support • Honoring DSCP and 802.1p • MAC Address Mapping to Priority Queue • Priority Queue Management using Weighted Round Robin (WRR), Strict Priority (SP), and a combination of WRR and SP • Priority Flow Control |
Traffic management | • ACL-based inbound rate limiting and traffic policies • Broadcast, multicast, and unknown unicast rate limiting • Inbound rate limiting per port • Outbound rate limiting per port and per queue |
Security | • MACsec • 802.1X authentication • MAC authentication • Flexible authentication • Web authentication • DHCP snooping • Dynamic ARP inspection • Neighbor Discovery (ND) Inspection • Tri-level Access Mode (EXEC, Privileged EXEC and Global Configuration) • EAP pass-through support • EEE 802.1X username export in sFlow • Protection against Denial of Service (DoS) attacks Authentication, Authorization, and Accounting (AAA) • MAC Address Locking MAC Port Security • Advanced Encryption Standard (AES) with SSHv2 • RADIUS/TACACS/TACACS+ • Secure Copy (SCP) • Secure Shell (SSHv2) • Local Username/Password • Change of Authorization (CoA) RFC 5176 • Trusted Platform Module • Protected ports • RADSEC (RFC 6614) • Encrypted Syslog (RFC 5425) |
High availability (require license) | • Redundant hot-swappable power supplies • Hot-swappable fan trays • Layer 3 VRRP/VRRP-E protocol redundancy • Real-time state synchronization across the stack • Hitless failover and switchover from master to standby stack controller • Hot insertion and removal of stacked units • Layer 2 VSRP switch redundancy • In Service Software Update (ISSU) |
SDN features | • Support for OpenFlow v1.0 and v1.3 • OpenFlow support with hybrid port mode • Operates with OpenDaylight SDN Controllers and the applications running on the controller |
STANDARD COMPLIANCE ICX 7650-48P | |
IEEE standards compliance | • 802.1AB LLDP • 802.1D MAC Bridging • 802.1p Mapping to Priority Queue • 802.1s Multiple Spanning Tree (MST) • 802.1w Rapid Reconfiguration of Spanning Tree • 802.1x Port-based Network Access Control (PNAC) • 802.3 Carrier Sense Multiple Access/Collision Detection (CSMA/CD) • 802.3ab 1000BASE-T • 802.1 AX-2008 Link Aggregation • 802.3ae 10 Gigabit Ethernet • 802.3af Power over Ethernet • 802.3at Power over Ethernet Plus • 802.3u 100Base-TX • 802.3x Full duplex and Flow Control • 802.3z 1000Base-SX/LX • 802.3 MAU MIB (RFC 2239) • 802.3ba 40 and 100 Gbps Ethernet • 802.1AE-MACsec (with license) • 802.3az Energy Efficient Ethernet • 802.1Q VLAN Tagging • 802.1BR Bridge Port Extension |
ENVIRONMENT ICX 7650-48P | |
Temperature | Operating temperature: 0°C to 45°C/32°F to 113°F at sea level Storage temperature: −40°C to 70°C/−40°F to 158°F |
Humidity | Operating relative humidity: 10% to 90% at 50°C, non-condensing Non-operating relative humidity: 5% to 95% at 70°C, non-condensing |
Altitude | Operating altitude: 10,000 ft (3,000 m) maximum Storage altitude: 39,000 ft (12,000 m) maximum |
COMPLIANCE/CERTIFICATION ICX 7650-48P | |
Electromagnetic emissions | FCC Class A (Part 15); EN 55022/CISPR-22 Class A; VCCI Class A; ICES-003 Electromagnetic Emission; AS/NZS 55022; EN 61000-3-2 Power Line Harmonics; EN 61000-3-3 Voltage Fluctuation and Flicker EN 61000-6-3 Emission Standard |
Safety | CAN/CSA-C22.2 NO. 60950-1-07; UL 60950-1; IEC60950-1; EN 60950-1:2006 Safety of Information Technology Equipment; EN 60825-1 Safety of Laser Products |
Immunity | EN 61000-6-1 Generic Immunity and Susceptibility; EN 55024 Immunity Characteristics; EN 61000-4-3 Radiated, Radio Frequency, Electromagnetic Field; EN 61000-4-4 Electrical Fast Transient; EN 61000-4-5 Surge; EN 61000-4-6 Conducted Disturbances Induced by Radio-Frequency Fields; EN 61000-4-8 Power Frequency Magnetic Field; EN 61000-4-11 Voltage Dips and Sags |
Environmental regulatory compliance | RoHS-compliant (6 of 6); WEEE-compliant |
Vibration | IEC 68-2-36, IEC 68-2-6 |
Shock and drop | IEC 68-2-27, IEC 68-2-32 |
Để cập nhật thông tin giá Thiết bị mạng RUCKUS mới nhất, quý khách hàng vui lòng liên hệ Hotline 0902 553 573 – 0978 68 88 78 hoặc Fanpage để được hỗ trợ tốt nhất.
Đánh giá
Chưa có đánh giá nào.